2x2/0+2/0awg Trophon Aluminum Conductor Triplex Overhead Service Drop Cable

Triplex Service Drop Cable 2/0AWG Trophon #2/0

Code Word: Trophon

Size AWG (Phase Conductors): 2/0

Voltage: 600V

Number of cores: Triplex

Package : Export wooden drum & iron wooden drum or as customer require

Email: manager@hdcable.com.cn

2/0-2/0-2/0 Trophon Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application


2/0-2/0-2/0 Trophon Aluminum Conductor Overhead Service Drop Cable Wirehas three conductors, with one of them being for neutral path, and two electrodes. The aluminum triplex cable is an electrical cable meant for power distributions from the utility lines to the consumer’s premises through the weather head. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.

2/0-2/0-2/0 Trophon Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard

• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts
CONSTRUCTION :

2/0-2/0-2/0 Trophon Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger)Conductor

Bare AAC messenger. Optional constructions include a messenger of AAC or ACSR.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.


TECHNICAL DATA :

2/0-2/0-2/0 Trophon Aluminum Conductor Triplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

V

600

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

 
PARAMETER :
2/0-2/0-2/0 Trophon Aluminum Conductor Triplex Overhead Service Drop Cable Wire Parameter
Code Name Trophon
Phase Conductor Material AAC
Phase Conductor Size (awg) 2/0
Phase Conductor Stranding 19
Phase Conductor insulation Material XLPE
Phase Conductor Insulation Thickness (mils) 60
Bare Neutral Messenger Material AAC
Bare Neutral Messenger Size(awg) 2/0
Bare Neutral Messenger Stranding 7
Bare Neutral Messenger Breaking Strength (Lbs) 2510
Weight Per (Lbs/1000 ft)  467
Ampacity (Amps) 235