SWA Steel Wire Armoured Control Cable
Voltage Rating: 450/750 Volts,
Conductor: soft annealed copper
Insulation: PVC
Armoured material Steel Wire Armoured
Sheath PVC
Email: manager@hdcable.com.cn
|
Model |
Name |
Main application |
|
KVV |
Copper conductor PVC insulated PVC sheathed control cable |
For laying indoors, in trenches and in ducts, for fixed installation |
|
KVVP |
Copper conductor PVC insulated PVC sheathed copper braiding screened control cable |
For laying indoors, in trenches and in dusts, for fixed installation |
|
KVVP2 |
Copper conductor PVC insulated and sheathed control cable with steel tape shield |
For laying indoors, in trenches and in dusts and in ground, able to withstand heavier mechanical force, for fixed installation |
|
KVV22 |
Copper conductor PVC insulated and sheathed control cable with steel tape armour |
For laying indoors, in trenches and in dusts and in ground, able to withstand heavier mechanical force, for fixed installation |
|
KVVR |
Copper conductor PVC insulated flexible control cable |
For laying indoors, movable and flexible |
|
ZR-KVVRP |
Copper conductor PVC insulated PVC sheathed flame retardant flexible control cable with braided shield |
Fixed laying indoors with capability of moving and screening |
|
ZR-KVV |
Copper conductor PVC insulated and sheathed flame retardant control cable |
For laying indoors, in trenches, in ducts and for fixed installation, the cable should be flame retardant |
|
ZR-KVVP2 |
Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape shield |
For laying indoors, in trenches, in ducts and for fixed installation, the cable should be flame retardant |
|
ZR-KVV22 |
Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape armour |
For laying indoors, in trenches, in ducts and underground, the cable should be flame-retardant and able to bear beavier external mechanical force, and for fixed installation |
|
ZR-KVVR |
Copper conductor PVC insulated and sheathed flame retardant flexible control cable |
For laying indoors, and the cable should be flexible and movablea |
| STANDARD | IEC 60227, IEC 60502, GB/T 9330, BS 6500 |
| APPLICATION | Industral Use |
| CHEMICAL PERFORMANCE | Chemical & Oil resistance: Good |
| MECHANICAL PERFORMANCE | Minimum bending raduis: x20cable diameter |
| FIRE PERFORMANCE | Flame non-propagation base on IEC 60332-1 Reduced emission of Halogens chlorine<15% |
| TERMINAL PERFORMANCE | Maximum service temperature: 70°C Maximum short-circuit temperature: 160°C(max. 5s) Minimum service temperature: -15°C |
| Nominal Size |
Conductor Structure | Insulation Thickness | Thickness of Inner Sheath |
Dia. of Steel Wire |
Sheath Thickness | Approx. Overall Dia. |
Approx. Weight | Nominal Size |
Conductor Structure | Insulation Thickness | Thickness of Inner Sheath |
Dia. of Steel Wire |
Sheath Thickness | Approx. Overall Dia. |
Approx. Weight |
| mm2 | No./mm | mm | mm | mm | mm | mm | kg/km | mm2 | No./mm | mm | mm | mm | mm | mm | kg/km |
| 3x0.75 | 1/0.97 | 0.6 | 1.1 | 1.6 | 1.5 | 13.29 | 419 | 3x0.75 | 7/0.37 | 0.6 | 1.1 | 1.6 | 1.5 | 13.63 | 435 |
| 4x0.75 | 1/0.97 | 0.6 | 1.1 | 1.6 | 1.5 | 13.92 | 457 | 4x0.75 | 7/0.37 | 0.6 | 1.1 | 1.6 | 1.5 | 14.29 | 476 |
| 5×0.75 | 1/0.97 | 0.6 | 1.1 | 1.6 | 1.5 | 14.61 | 501 | 5×0.75 | 7/0.37 | 0.6 | 1.1 | 1.6 | 1.5 | 15.03 | 522 |
| 6×0.75 | 1/0.97 | 0.6 | 1.1 | 1.6 | 1.5 | 15.33 | 547 | 6×0.75 | 7/0.37 | 0.6 | 1.1 | 1.6 | 1.5 | 15.80 | 571 |
| 7×0.75 | 1/0.97 | 0.6 | 1.1 | 1.6 | 1.5 | 15.33 | 552 | 7×0.75 | 7/0.37 | 0.6 | 1.1 | 1.6 | 1.5 | 15.80 | 577 |
| 8x0.75 | 1/0.97 | 0.6 | 1.1 | 1.6 | 1.5 | 15.86 | 588 | 8x0.75 | 7/0.37 | 0.6 | 1.2 | 1.6 | 1.5 | 16.37 | 615 |
| 10x0.75 | 1/0.97 | 0.6 | 1.2 | 1.6 | 1.5 | 17.33 | 676 | 10x0.75 | 7/0.37 | 0.6 | 1.2 | 1.6 | 1.5 | 17.96 | 710 |
| 12x0.75 | 1/0.97 | 0.6 | 1.2 | 1.6 | 1.5 | 17.71 | 710 | 12x0.75 | 7/0.37 | 0.6 | 1.2 | 1.6 | 1.5 | 18.35 | 745 |
| 14x0.75 | 1/0.97 | 0.6 | 1.2 | 1.6 | 1.5 | 18.33 | 760 | 14x0.75 | 7/0.37 | 0.6 | 1.2 | 1.6 | 1.5 | 18.82 | 789 |
| 16x0.75 | 1/0.97 | 0.6 | 1.2 | 1.6 | 1.5 | 18.82 | 807 | 16x0.75 | 7/0.37 | 0.6 | 1.2 | 1.6 | 1.7 | 19.96 | 867 |
| 19x0.75 | 1/0.97 | 0.6 | 1.2 | 1.6 | 1.7 | 19.95 | 888 | 19x0.75 | 7/0.37 | 0.6 | 1.2 | 1.6 | 1.7 | 20.73 | 934 |
| 24x0.75 | 1/0.97 | 0.6 | 1.2 | 1.6 | 1.7 | 21.95 | 1034 | 24x0.75 | 7/0.37 | 0.6 | 1.2 | 1.6 | 1.7 | 22.88 | 1090 |
| 27x0.75 | 1/0.97 | 0.6 | 1.2 | 1.6 | 1.7 | 22.32 | 1080 | 27x0.75 | 7/0.37 | 0.6 | 1.2 | 1.6 | 1.7 | 23.28 | 1138 |
| 30x0.75 | 1/0.97 | 0.6 | 1.2 | 1.6 | 1.7 | 22.95 | 1142 | 30x0.75 | 7/0.37 | 0.6 | 1.2 | 1.6 | 1.7 | 23.95 | 1204 |
| 37x0.75 | 1/0.97 | 0.6 | 1.2 | 1.6 | 1.7 | 24.36 | 1285 | 37x0.75 | 7/0.37 | 0.6 | 1.2 | 1.6 | 1.7 | 25.26 | 1344 |
| 44x0.75 | 1/0.97 | 0.6 | 1.2 | 1.6 | 1.7 | 26.58 | 1470 | 44x0.75 | 7/0.37 | 0.6 | 1.2 | 1.6 | 1.7 | 27.61 | 1534 |
| 48x0.75 | 1/0.97 | 0.6 | 1.2 | 1.6 | 1.7 | 26.74 | 1509 | 48x0.75 | 7/0.37 | 0.6 | 1.2 | 1.6 | 1.7 | 27.81 | 1581 |
| 52x0.75 | 1/0.97 | 0.6 | 1.2 | 1.6 | 1.7 | 27.37 | 1583 | 52x0.75 | 7/0.37 | 0.6 | 1.2 | 1.6 | 1.7 | 28.48 | 1659 |
| 61x0.75 | 1/0.97 | 0.6 | 1.2 | 1.6 | 2.0 | 29.18 | 1777 | 61x0.75 | 7/0.37 | 0.6 | 1.2 | 1.6 | 2.0 | 30.58 | 1878 |